AMPM Solar logoAMPM SolarUK

🇬🇧 United Kingdom

Projects

Reference configurations showing how commercial solar, storage, HVAC and charging come together on different site types. Filter by market to see the connection route and funding position that applies.

These are indicative reference configurations based on typical commercial installations, not named client case studies. Figures are modelled examples — your own site will differ.

Manufacturing🇬🇧 United Kingdom

Light manufacturing rooftop array

North West England · 400 kWp rooftop PV

Two-shift operation with a strong daytime baseload. Sized against the half-hourly profile to keep export low and capital allowance relief meaningful.

  • · Trapezoidal-sheet mounting with structural appraisal first
  • · G99 application to the regional DNO
  • · Capital allowances modelled: AIA on the first £1m, 50% FYA on the balance
~82%
generation used on site
SEG
tariff for the exported balance
0% VAT
position confirmed before order
Retail🇬🇧 United Kingdom

Retail park multi-unit rooftop

Midlands, England · 310 kWp across four units

Landlord-led installation across separately metered units, with lighting and cooling load aligning closely with generation.

  • · Four separate arrays, one per metered unit
  • · G99 application covering the aggregate connection
  • · Per-unit monitoring for tenant recharging
Per unit
generation metered and allocated
Summer peak
cooling load matched to output
Phased
installation with no trading disruption
Agriculture🇬🇧 UK & 🇮🇪 Ireland

Dairy farm solar and hot water load

Rural site, UK or Ireland · 90 kWp rooftop PV

Milking, vacuum pumps, plate cooling and water heating give an unusually good daytime match. Sheds provide clear, unshaded south-facing roof area.

  • · Modules across two shed roofs
  • · Diverter to the hot water cylinder for surplus
  • · Sized to the milking schedule rather than the roof
Twice daily
load aligned to generation
Surplus
diverted to water heating before export
Low
shading and structural risk
Offices🇬🇧 UK & 🇮🇪 Ireland

Office HQ with VRF cooling and solar

Urban site, UK or Ireland · 120 kWp PV with VRF air conditioning

Cooling demand peaks with solar output, so nearly all generation is consumed on site during the months the array produces most.

  • · Roof array plus VRF indoor and outdoor units supplied together
  • · Controls tuned so cooling leans on generation
  • · EV charging provision with dynamic load management
Peak match
cooling and generation coincide
One supplier
for PV, HVAC and charging
Headroom
kept for future EV charging

Have a site in mind?

Send us the roof area, sector and annual consumption and we'll come back with an indicative specification for the United Kingdom.